Home Products Applications Tech. service Price List Special price Catalog Download Corporate Culture Contact Us
SIEMENS PLC & HMI
SIEMENS AC&DC DRIVE
SIEMENS LV/HV Switches
SIEMENS Instruments
SIEMENS BuildingTech &Burner
MITSUBISHI PLC/DRIVES
TOSHIBA & OMRON autumation
DELTA Automation
YASKAWA. PANASONIC.FUJI
PARKER DRIVE& EUROTHERM METER
Schneider Automation
AB/GE/Honeywell
LENZE. SEW & Control Techniques
DANFOSS Products
SMC & FESTO+AIRTAC (Pneumatic)
FATEK.XINJE(PLC. HMI.)
TURCK.SICK.IFM&P+F.Phoenix
HITECH. FOTEK.ALPHA
KOYO. KEYENCE&SUNX
Weintek.Proface HMI
Instrument(Yokogawa &E+H )
Advantech & HUST CNC
LG & Autonics
Gearbox.Line Rail. Valve
Spare part(IGBT,Thyristor,Circuit board)

Products 

 

Panasonic PLC- FP0R series (mini)

Model No.︰FP0R
Brand Name︰PANASONIC
Country of Origin︰Japan
Minimum Order︰1 pc
Share on:

 Total 13 Related Items 
Prev7891011Next

Product Description

 1.  Control units

Product name Built-in memory 
(Program capacity)
Specifications Part Number
Number of I/O points Power supply
voltage
Input Output Connection type
FP0R-C10 Control Unit EEPROM
(16 k steps)
10 Input: 6
Output: 4
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RC10RS
Molex connector AFP0RC10RM
FP0R-C10 Control Unit
with RS232C port
EEPROM
(16 k steps)
10 Input: 6
Output: 4
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RC10CRS
Molex connector AFP0RC10CRM
FP0R-C10 Control Unit
with RS485 port
EEPROM
(16 k steps)
10 Input: 6
Output: 4
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RC10MRS
FP0R-C14 Control Unit EEPROM
(16 k steps)
14 Input: 8
Output: 6
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RC14RS
Molex connector AFP0RC14RM
FP0R-C14 Control Unit
with RS232C port
EEPROM
(16 k steps)
14 Input: 8
Output: 6
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RC14CRS
Molex connector AFP0RC14CRM
FP0R-C14 Control Unit
with RS485 port
EEPROM
(16 k steps)
14 Input: 8
Output: 6
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RC14MRS
FP0R-C16 Control Unit EEPROM
(16 k steps)
16 Input: 8
Output: 8
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RC16T
Transistor PNP: 0.2 A AFP0RC16P
FP0R-C16 Control Unit
with RS232C port
EEPROM
(16 k steps)
16 Input: 8
Output: 8
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RC16CT
Transistor PNP: 0.2 A AFP0RC16CP
FP0R-C16 Control Unit
with RS485 port
EEPROM
(16 k steps)
16 Input: 8
Output: 8
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RC16MT
Transistor PNP: 0.2 A AFP0RC16MP
FP0R-C32 Control Unit EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RC32T
Transistor PNP: 0.2 A AFP0RC32P
FP0R-C32 Control Unit
with RS232C port
EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RC32CT
Transistor PNP: 0.2 A AFP0RC32CP
FP0R-C32 Control Unit
with RS485 port
EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RC32MT
Transistor PNP: 0.2 A AFP0RC32MP
FP0R-T32 Control Unit
with RS232C port and
Real-time clock function
EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RT32CT
Transistor PNP: 0.2 A AFP0RT32CP
FP0R-T32 Control Unit
with RS485 port and
Real-time clock function
EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RT32MT
Transistor PNP: 0.2 A AFP0RT32MP
FP0R-F32 Control Unit
with RS232C port and
Battery-less
automatic all data
backup function
EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RF32CT
Transistor PNP: 0.2 A AFP0RF32CP
FP0R-F32 Control Unit
with RS485 port and
Battery-less
automatic all data
backup function
EEPROM
(32 k steps)
32 Input: 16
Output: 16
24 V DC 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.2 A MIL connector AFP0RF32MT
Transistor PNP: 0.2 A AFP0RF32MP
Note : A power cable (Part number: AFPG805) is supplied with the control units.

Return to top


2. Expansion units

Product name Specications Part number
Number of I/O points Power supply
voltage
Input Output Connection type
FP0R-E8
Expansion Unit
8 Input: 8 - 24 V DC
Sink/Source
(±common)
- MIL connector AFP0RE8X
8 Input: 4
Output: 4
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RE8RS
Molex connector AFP0RE8RM
8 Output: 8 24 V DC - Relay: 2 A Terminal block AFP0RE8YRS
8 Output: 8 - - Transistor NPN: 0.3 A MIL connector AFP0RE8YT
8 Output: 8 - - Transistor PNP: 0.3 A MIL connector AFP0RE8YP
FP0R E16
Expansion Unit
16 Input: 16 - 24 V DC
Sink/Source
(±common)
- MIL connector AFP0RE16X
16 Input: 8
Output: 8
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RE16RS
Molex connector AFP0RE16RM
16 Input: 8
Output: 8
- 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.3 A MIL connector AFP0RE16T
16 Input: 8
Output: 8
- 24 V DC
Sink/Source
(±common)
Transistor PNP: 0.3 A MIL connector AFP0RE16P
16 Output: 16 - - Transistor NPN: 0.3 A MIL connector AFP0RE16YT
16 Output: 16 - - Transistor PNP: 0.3 A MIL connector AFP0RE16YP
FP0R E32
Expansion Unit
32 Input: 16
Output: 16
- 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.3 A MIL connector AFP0RE32T
32 Input: 16
Output: 16
- 24 V DC
Sink/Source
(±common)
Transistor PNP: 0.3 A MIL connector AFP0RE32P
*1 The relay output type expansion units come with a power cable (part number: AFP0581).
(The transistor output type expansion units need no power cable.)
*2 The terminal block type relay output units have two terminal blocks (9 pins) made by Phoenix.
Use a 2.5 mm 0.10 inch wide screwdriver. Preferably use the specific terminal block screwdriver (part number: AFP0806, Phoenix type code SZS0, 4 x 2.5 mm 0.10 inch) or equivalent.
*3 The connector type relay output units have two connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). Use the specific Molex connector press-fit tool (part number: AFP0805, Nihon Molex type code 57189-5000) or equivalent.
*4 The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number: AXY52000FP) for wire-pressed terminal cable.

Return to top


3. Intelligent units

Easy backward compatibility

Use compatibility mode to retain existing ladder programming.
You can use a DIP switch to enable compatibility mode, which allows operation at 12-bit resolution (using program resources).

 

■PREVIOUS MODEL SUBSTITUTION TABLE

Analog type Previous model New model
Input - AFP0RAD4
AFP0401 AFP0RAD8
Output Voltage AFP04121 AFP0RDA4
Current AFP04123
Input / Output AFP0480 AFP0RA21
- AFP0RA42
Product name Number of channels Part No.
FP0R Analog input unit Input: 4 channels NEW
AFP0RAD4
Input: 8 channels NEW
AFP0RAD8
FP0R Analog I/O unit Input: 2 channels / Output: 1 channel NEW
AFP0RA21
Input: 4 channels / Output: 2 channels NEW
AFP0RA42
FP0R Analog output unit Output: 4 channels NEW
AFP0RDA4
FP0 Thermocouple Unit K, J, T and R thermocouple, Resolution: 0.1 ℃ AFP0420
K, J, T and R thermocouple, Resolution: 0.1 ℃ AFP0421

Return to top


4. Link and Communication units[Units in common with FP0]

Product name Specications Power supply
voltage
Product number Part number
FP0 CC-Link Slave Unit This unit is for making the FP0 function as a slave station of the CC-Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
Note : Accuracy will change if an FP0 thermocouple unit is used at the same time.
For details, please refer to the catalog or to the CC-Link Unit manual.
24 V DC FP0-CCLS AFP07943
Specifications︰The control unit is only 25mm, even extending to 128 points of I/O, and the width is only 105mm.

I/O 32-point control unit and S-LINK control unit have a width of 30mm
The minimum size of the control unit is W25 x H90 x D60mm.
In addition, the maximum can be expanded to 128 points. The size at this time is W105 × H90 × D60mm. The ultra-small form factor breaks the way people think about small PLCs. From the perspective of the installation area, it contributes to the miniaturization of the machine control panel.

There are 3 ways to install it.
DIN rail mounting
Directly mounted on the underside
Direct attachment (※)

Not available for expansion module
Use up to three expansion units. No cables are required for stacking.
The expansion unit can be connected directly to the control unit. The expansion unit can form a laminated system using the surface expansion connector and locking a single row of contacts without the need for special extension cables, backplanes, and the like.


Whether it is an end block or a connector, simply moving the terminal part can be easily wired.

Terminal block
The terminal block can be directly inserted without the need to rotate or squeeze (European manufactured by Phoenix) to handle wires from 0.2 to 1.25 mm2.

Compatible model:

FP0-C10RS, C10CRS, C14RS, C14CRS, E8RS, E8YRS, E16RS
Advantages︰Specialty

1. Small size W25×H90×D60mm.
In terms of size, it is superior to a general small PC, and combined control with the machine contributes to the miniaturization of the control unit.

The control unit width of 32 points is W30mm.

2. The maximum can be expanded to 3 units and 128 points.
A stack expansion method that does not require an extension cable is used. In the case of an expansion of 3 units, a width of only 105 mm is very space-saving.

3. High-speed operation with a scan time of approximately 1ms.
The 500-step program can be processed in just 1 ms. The processing speed can fully meet the needs of small PLCs.

4. Fit the terminal shape of the small body.
The relay output type adopts the European terminal block method.
Wiring can be performed after removing the terminal block. The mass-produced unit is equipped with a Molex connector type terminal.
Transistor output type comes with a loose wire connector

5. The product with the program capacity of 10K is the latest

The standard is equipped with a calendar hanging clock and an RS232C port.
The operation memory is backed up using the secondary battery.
Min Order︰1
Ship Date︰ON STOCKS
Standard Met︰ul vde ce ccc
Product Image


Related Products
Yaskawa CIMR-H1000  inverter
Yaskawa CIMR-H1000 inverter
Yaskawa V1000 series AC inverter
Yaskawa V1000 series AC inverter
Yaskawa AC drives A1000 series, 0.4-355KW
Yaskawa AC drives A1000 series, 0.4-355KW
(new! )Yaskawa J1000 series-small type
(new! )Yaskawa J1000 series-small type

Home  |  Products  |  Applications  |  Tech. service  |  Price List  |  Special price  |  Catalog Download  |  Corporate Culture  |  Contact Us  |  Sitemap  |  Mobile Version
  English     简体版     繁體版
Powered by DIYTrade.com
HomeContact UsSitemap